NMS connection to N2000 BMS
# if vlan 10 is being use for NMS connection on metro
|
||||
|
||||
Interface eth
ip modify 172.29.219.10
ip_address 192.168.0.3
submask 255.255.255.0 gateway
192.168.0.1 vlan_tag 10
quit
qos ip 192.168.0.3 strategy tos
qos ip 192.168.0.3 tos maintain 1 0
sysname MSANNB00-D2-KBB
snmp-agent community read public
snmp-agent community write private
snmp-agent target-host trap address 10.10.10.2 securityname huawei v1
snmp-agent trap
enable standard
autosave interval on
Working mode integrated
uplink tps on
Create additional
admin user on PVMD board
terminal user
Command:
terminal
user name
User
Name(length<6,15>):admin
The user name must
be equal to or more than 6 characters
User
Name(length<6,15>):admin
The user name must
be equal to or more than 6 characters
User
Name(length<6,15>):admin123
User
Password(length<8,15>): r00tw3rk#@!
Confirm
Password(length<8,15>):
User profile
name(<=15 chars)[root]:
User's Level:
1. Common
User 2. Operator 3. Administrator:3
Permitted Reenter
Number(0--4):4
User's Appended
Info(<=30 chars):working
Adding user succeeds
Repeat this
operation? (y/n)[n]:n
Board confirmation
on PVMD frame (indoor)
UA5000(config)#frame add 0 # adding the HABA main master frame
FrameType:
0 :
MAIN_HABM_30(HABA) 1 : MAIN_HAFM_30(HABD)
2 : MAIN_HAFM_6(HABL) 3 : MAIN_H602HABD(HABD)
4 : MAIN_H601HABC(HABC) 5
: SLAVE_HAFS_32(HABE)
6 : SLAVE_HABS_32(HABB) 7 :
SLAVE_HABS_30(HABA)
8 : SLAVE_HAFS_30(HABD) 9
: SLAVE_H602HABD(HABD)
10 : SLAVE_H602HABE(HABE) 11
: RSU_HAFS_30(HABD)
12 : RSU_HABS_30(HABA) 13 : RSU_HAFS_12(HABC)
14 : RSU_HAFS_6(HABL) 15
: RSUG_ONU60A(HUBO)
16 : RSUG_ONU04A 17 : RSUG_ONU08A
18 : RSP_19(HCB) 19 : RSP_15(HDB)
20 : RSP_14(HIB) 21 : RSP_12(HFB)
22 :
RSP_10(HGB) 23 : RSP_6A(HMB)
24 : RSP_6B(HLB) 25 : UAM_R (HUBM)
26 : UAS_R (HUBS) 27 : UAFM_R(HUBE)
28 : UAFS_R(HUBF) 29 : UAMB_R(HUBB)
30 : ONU60A_R(HUBO) 31 : ONUF01D100_R(HUBL)
32 : VRSP_12(HABA) 33 : VRSP_18(HABA)
34 : HWTA(HIB_1) 35 : HWTA(HIB_2)
36 : HWTA(HIB_3)
Please select frame type (0 ~ 36): 0
UA5000(config)#frame add 1 # adding the HABA slave frame
FrameType:
0 : MAIN_HABM_30(HABA) 1 : MAIN_HAFM_30(HABD)
2 : MAIN_HAFM_6(HABL) 3 : MAIN_H602HABD(HABD)
4 : MAIN_H601HABC(HABC) 5
: SLAVE_HAFS_32(HABE)
6 : SLAVE_HABS_32(HABB) 7 : SLAVE_HABS_30(HABA)
8 : SLAVE_HAFS_30(HABD) 9
: SLAVE_H602HABD(HABD)
10 : SLAVE_H602HABE(HABE) 11
: RSU_HAFS_30(HABD)
12 : RSU_HABS_30(HABA) 13 : RSU_HAFS_12(HABC)
14 : RSU_HAFS_6(HABL) 15 : RSUG_ONU60A(HUBO)
16 :
RSUG_ONU04A 17 : RSUG_ONU08A
18 : RSP_19(HCB) 19 : RSP_15(HDB)
20 : RSP_14(HIB) 21 : RSP_12(HFB)
22 : RSP_10(HGB) 23
: RSP_6A(HMB)
24 : RSP_6B(HLB) 25 : UAM_R (HUBM)
26 : UAS_R (HUBS) 27 : UAFM_R(HUBE)
28 : UAFS_R(HUBF) 29 : UAMB_R(HUBB)
30 : ONU60A_R(HUBO) 31 : ONUF01D100_R(HUBL)
32 : VRSP_12(HABA) 33 : VRSP_18(HABA)
34 : HWTA(HIB_1) 35 : HWTA(HIB_2)
36 :
HWTA(HIB_3)
Please select frame type (0 ~ 36): 7
frame connect 0 1 # must connect the HW cable behind the HABA frame master
& slave! Compulsory..
Board confirm 0
Board confirm 1
board add
{ frameid/slotid<S><1,15> }:0/6 ?
Command:
board add
0/6 ?
---------------------------------------------
Command of config
Mode:
---------------------------------------------
A32 32-port analog subscriber line board
ASL 16-port analog subscriber line board
ATI Analog trunk interface board
CDI 16-port direct dial-in subscriber
interface board
CSM 16-port analog subscriber line board
CSR 32-port analog subscriber line board
DSL Digital subscriber line board
H301HWTA Remote subscriber processing board
H601DSLD 16-port Digital subscriber line board
H601DSLE 16-port Digital subscriber line board
H601EDTB 16-port E1 conversion board
H601PVMB Protocol processing and main node board
H602PWX
Secondary power board
H602RSUG 2-port G.SHDSL and 1-port E1 Remote subscriber
processing board
H611SDLE 8-port G.SHDSL and 8-port E1 conversion board
H612EDTB 16-port
E1 conversion board
HSL High speed synchronization line board
PWX2 Secondary power board
PWX3 Secondary power board
PWXA Secondary power board
RSP Remote subscriber processing board
RSU4 4-port E1 Remote subscriber processing
board
RSU8 8-port E1 Remote subscriber processing
board
SDL 4-port G.SHDSL and 4-port E1 conversion board
TSS Subscriber test board
VFB Voice frequency board
# can add highlighted board on PVMD
# after adding board please execute as below:-
Board confirm 0
Board confirm 1
# until will get normal condition for the board. Execute
“display board 0”
Board delete 0/0
Board add 0/0 H602PWX
Board confirm 0
# delete and add one by one until each of these
board are in normal condition!
# CAUTION!! Don’t delete both in the
same time without waiting one of these boards are in normal condition!!!! It will caused the PVMD in a unstable
condition..
Board delete 0/1
Board add 0/1 H602PWX
Board confirm 0
Board confirmation
on PVMD frame (outdoor)
UA5000(config)#frame add 0 # adding the HABD main master frame
FrameType:
0 : MAIN_HABM_30(HABA) 1 : MAIN_HAFM_30(HABD)
2 : MAIN_HAFM_6(HABL) 3 : MAIN_H602HABD(HABD)
4 : MAIN_H601HABC(HABC) 5
: SLAVE_HAFS_32(HABE)
6 : SLAVE_HABS_32(HABB) 7
: SLAVE_HABS_30(HABA)
8 : SLAVE_HAFS_30(HABD) 9
: SLAVE_H602HABD(HABD)
10 : SLAVE_H602HABE(HABE) 11
: RSU_HAFS_30(HABD)
12 : RSU_HABS_30(HABA) 13 : RSU_HAFS_12(HABC)
14 : RSU_HAFS_6(HABL) 15 : RSUG_ONU60A(HUBO)
16 :
RSUG_ONU04A 17 : RSUG_ONU08A
18 : RSP_19(HCB) 19 : RSP_15(HDB)
20 : RSP_14(HIB) 21 : RSP_12(HFB)
22 : RSP_10(HGB) 23 : RSP_6A(HMB)
24 : RSP_6B(HLB) 25 : UAM_R (HUBM)
26 : UAS_R (HUBS) 27 : UAFM_R(HUBE)
28 : UAFS_R(HUBF) 29 : UAMB_R(HUBB)
30 : ONU60A_R(HUBO) 31 : ONUF01D100_R(HUBL)
32 : VRSP_12(HABA) 33 : VRSP_18(HABA)
34 : HWTA(HIB_1) 35 : HWTA(HIB_2)
36 :
HWTA(HIB_3)
Please select frame type (0 ~ 36): 3
UA5000(config)#frame add 1 # adding the HABD slave frame
FrameType:
0 : MAIN_HABM_30(HABA) 1 : MAIN_HAFM_30(HABD)
2 : MAIN_HAFM_6(HABL) 3 : MAIN_H602HABD(HABD)
4 : MAIN_H601HABC(HABC) 5
: SLAVE_HAFS_32(HABE)
6 : SLAVE_HABS_32(HABB) 7
: SLAVE_HABS_30(HABA)
8 :
SLAVE_HAFS_30(HABD) 9 : SLAVE_H602HABD(HABD)
10 : SLAVE_H602HABE(HABE) 11
: RSU_HAFS_30(HABD)
12 : RSU_HABS_30(HABA) 13 : RSU_HAFS_12(HABC)
14 : RSU_HAFS_6(HABL) 15 : RSUG_ONU60A(HUBO)
16 :
RSUG_ONU04A 17 : RSUG_ONU08A
18 : RSP_19(HCB) 19 : RSP_15(HDB)
20 : RSP_14(HIB) 21 : RSP_12(HFB)
22 : RSP_10(HGB) 23 : RSP_6A(HMB)
24 : RSP_6B(HLB) 25 : UAM_R (HUBM)
26 :
UAS_R (HUBS) 27 : UAFM_R(HUBE)
28 : UAFS_R(HUBF) 29 : UAMB_R(HUBB)
30 : ONU60A_R(HUBO) 31 : ONUF01D100_R(HUBL)
32 : VRSP_12(HABA) 33 : VRSP_18(HABA)
34 : HWTA(HIB_1) 35 : HWTA(HIB_2)
36 :
HWTA(HIB_3)
Please select frame type (0 ~ 36): 8
frame connect 0 1 # must connect the HW cable between HWCF to HWTF via HWOUT1
from HWCF and HWIN0 from HWTF.
# for HABD to HABF only need to connect
HWOUT0 from HWCF from HABD to HWIN0 from HWTF on HABF extended frame. No need
to add frame and connect it. Automatically HABD frame will have from 0-17 and
18-35 slots.
# 1 HABD + 1 HABF frames only for D200 &
D500 cabinet configuration.
# 2 HABD + 1 HABF frames is for D1000
cabinet configuration.
Board confirm 0
Board confirm 1
board add
{ frameid/slotid<S><1,15> }:0/6 ?
Command:
board add
0/6 ?
---------------------------------------------
Command of config
Mode:
---------------------------------------------
A32 32-port analog subscriber line board
ASL 16-port analog subscriber line board
ATI Analog trunk interface board
CDI 16-port direct dial-in subscriber
interface board
CSM 16-port analog subscriber line board
CSR 32-port analog subscriber line board
DSL Digital subscriber line board
H301HWTA Remote subscriber processing board
H601DSLD 16-port Digital subscriber line board
H601DSLE 16-port Digital subscriber line board
H601EDTB 16-port E1 conversion board
H601PVMB Protocol processing and main node board
H602PWX
Secondary power board
H602RSUG 2-port G.SHDSL and 1-port E1 Remote subscriber
processing board
H611SDLE 8-port G.SHDSL and 8-port E1 conversion board
H612EDTB 16-port
E1 conversion board
HSL High speed synchronization line board
PWX2 Secondary power board
PWX3 Secondary power board
PWXA Secondary power board
RSP Remote subscriber processing board
RSU4 4-port E1 Remote subscriber processing
board
RSU8 8-port E1 Remote subscriber processing
board
SDL 4-port G.SHDSL and 4-port E1 conversion board
TSS Subscriber test board
VFB Voice frequency board
# can add highlighted board on PVMD
# after adding board please execute as below:-
Board confirm 0
Board confirm 1
# until will get normal condition for the board. Execute
“display board 0”
Board delete 0/0
Board add 0/0 H602PWX
Board confirm 0
# delete and add one by one until each of these
board are in normal condition!
# CAUTION!! Don’t delete both in the
same time without waiting one of these boards are in normal condition!!!! It will caused the PVMD in a unstable
condition..
Board delete 0/1
Board add 0/1 H602PWX
Board confirm 0
H.248 Voice over
IP connection to Softswitch
On IPMD configure as below:-
Vlan 100 smart
Port vlan 100 0/2 0,6-7
Vlan 101 smart
Port vlan 101 0/2 0,6-7
#configuration on PVMD
Interface eth #configure second IP
for H.248
ip address 192.168.1.2 255.255.255.252 192.168.1.1 vlan_tag 100
quit
Interface eth #configure third IP
for media
ip address 192.168.1.6 255.255.255.252 192.168.1.5 vlan_tag 101
quit
interface h248 0
if-h248 attribute mgip 192.168.1.2 mgport 2944 mg-media-ip
192.168.1.6
transfer udp mgcip_1 <softswitch_IP> mgcport_1 2944
if-h248 attribute start-negotiate-version 1 deviceName
MSAN_Huawei
quit
# By default, UA5000 PVMD will use prefix A for its TID and 100000001
for RTP para-list. Other brand of Soft-switch may use different configuration.
Please ask Soft-switch engineer.
qos ip 192.168.1.2 strategy tos
qos ip 192.168.1.2 tos signalling 3 5
qos ip 192.168.1.6 strategy tos
qos ip 192.168.1.6 tos media 2 5
# creating H248 user on UA5000
Esl user
mgpstnuser batadd 0/6/0 1/35/31 0 terminalid 0 telno 42560000 step 1
|
|
|

quit
Configuring Inner
Digitmap for emergency calling within the same MGID
interface h248 0
mg-software parameter 11 3
display mg-software parameter 11
-------------------------------------------------
Interface Id:1 para index:11
value:3
-------------------------------------------------
APPENDIX:
-------------------------------------------------
Interface soft parameter name:
11: Stand alone support
0 : None
1 : Inner
2 : Emergency
3 : Both
standalone parameters dialtone 15
ring 60 busytone 50
display standalone parameters
--------------------------------------------------------------------------
System stand alone para of timer
for dial tone :15 (s)
System stand alone para of timer
for busy tone :50 (s)
System stand alone para of timer
for ring :60 (s)
--------------------------------------------------------------------------
digitmap set inner xxxxxxxx
display digitmap
---------------------------------------------------------------------------
Inner digitmap : xxxxxxxx
Emergency digitmap : -
Urgent digitmap (for overload or
bandwidth restrict) : -
Dualdial digitmap for card service
: -
---------------------------------------------------------------------------